High heat density
Move heat from LEDs, power semiconductors or concentrated device areas toward a defined metal and heat-sink interface.
Use an aluminum or copper base to move heat through the PCB. Direct thermal path options are available for selected designs. EBest PCBA reviews the metal base, dielectric, copper, board thickness, voltage withstand, routing and assembly requirements before quotation.
First response target: within 12 hours · Final materials, construction, testing and lead time confirmed from project files
Common thermal conductivity range for standard metal-core laminates.
Material availability and construction are confirmed from the project requirements.
Common production range; tolerance depends on the final construction.
Heavier copper combinations require engineering review.
An MCPCB helps transfer heat away from high-power components and spread it through the metal base. The right construction depends on power density, electrical insulation, current requirements, assembly design, and the cooling method used in the final product.
Move heat from LEDs, power semiconductors or concentrated device areas toward a defined metal and heat-sink interface.
Coordinate copper weight and conductor geometry with thermal spreading; thermal conductivity alone does not determine board performance.
Review flatness, finished thickness, holes, outline, V-cut and contact surface against the enclosure or heat sink.
Confirm the soldering profile, component keep-outs, fixture support and back-side contact before assembly.
Aluminum and copper are the main metal-base options. Direct thermal path structures are used when a device needs a shorter path to the metal base while maintaining the required electrical isolation and assembly conditions.
A common choice for lighting, control and power products that need heat spreading with electrical isolation.
Copper core boards suit higher heat and current demands when the added weight and cost are acceptable.
The values below show our common production range. Final capability depends on the full combination of metal type, dielectric, copper, thickness, hole size, line geometry, surface finish and mechanical requirements.
| Capability item | Standard Capability | Special Review |
|---|---|---|
| Material system | Aluminum or copper metal-base laminate; 1, 2 and 3 W/m·K material families | 3–8 W/m·K high-conductivity material, special dielectric, copper-aluminum composite or customer-specified family |
| Construction | Single-sided and double-sided metal-core PCBs; selected two-circuit-layer constructions | Direct thermal path, thermoelectric separation, special multilayer or complex mechanical integration |
| Finished thickness | 0.8–3.0 mm | 0.4–1.0 mm bendable aluminum constructions and 4.0–5.0 mm boards require special review |
| Copper weight | Inner 0.5–3 oz; outer 1–3 oz | Heavier copper reviewed against line geometry, etching, flatness and thermal demand |
| Working size | Up to 480 × 1180 mm for standard aluminum materials | Selected single-sided aluminum boards up to 1600 × 480 mm, subject to panel and handling review |
| Finished PTH | 0.45 mm minimum reference | 0.30 mm minimum subject to aspect ratio, plating and registration assessment |
| Line / space | 0.20 / 0.20 mm at 1 oz reference | 0.15 / 0.15 mm and copper-dependent finer combinations require special review |
| Surface finish | HASL, OSP, ENIG, immersion silver, immersion tin and plated gold requirements can be reviewed | Wire bonding, selective finish and direct-thermal-path combinations require process-specific confirmation |
| Outline and V-cut | Outline tolerance ±0.15 mm; V-cut typically used with 0.8–3.5 mm board thickness | ±0.10 mm outline targets, thick-board V-cut and special chamfer or carved features require special review |
These values are general capability ranges. Final manufacturability, tolerances, material availability, inspection requirements and lead time are confirmed after reviewing the complete project files.
A metal-core stack combines the aluminum or copper base, thermal dielectric, circuit copper, surface finish and back-side interface. These elements must meet the thermal, electrical, mechanical and assembly requirements together.
Common for lighting and power products that need a balance of heat spreading, mechanical rigidity, cost and production efficiency.
Selected when heat concentration, current, machining or mechanical interfaces justify the added weight and cost of a copper metal base.
Conductivity, dielectric thickness, voltage withstand, adhesion and thermal cycling are confirmed together rather than maximizing one value.
Copper weight, solderable finish, optional back-side protection, flatness and interface material complete the board’s thermal and assembly interface.
Operating temperature depends on the complete thermal path from the component junction through the pad, copper, dielectric, metal base, interface material and external heat sink. EBest PCBA reviews the PCB stack and heat-sink interface together.
Before production, we check the material stack, thermal targets, conductor geometry, holes, outline and assembly requirements that can affect manufacturability.
Confirms metal base, dielectric, copper, solder mask, finish and any direct-thermal-path feature.
Checks conductivity and dielectric thickness against electrical isolation and operating environment.
Reviews copper weight, line width, spacing, pads and local heat-spreading areas together with etching limits.
Coordinates PTH, NPTH, slots, edge distance, plated features and insulation around the metal base.
Examines tolerances, V-cut, routing, chamfer, flatness, fasteners and the heat-sink contact surface.
Checks surface finish, soldering profile, fixture support, component height and back-side contact.
The process covers material preparation, circuit formation, drilling and insulation, solder mask and surface finish, profiling, electrical testing and final inspection. Exact steps depend on the approved construction.
Confirm Gerber files and drawings, aluminum or copper selection, layer structure, thermal requirements, voltage withstand and assembly inputs.
Verify material family, conductivity class, dielectric thickness, metal base, finished thickness and copper weight.
Control imaging and etching according to the specified copper weight and line geometry.
Process PTH, NPTH, slots and special separation features against hole, plating and insulation requirements.
Apply solder mask, legend and the specified HASL, OSP, ENIG, silver, tin or plated-gold finish.
Control routing, outline tolerance, slots, edge clearance, V-cut angle and residual thickness.
Verify continuity, isolation, dimensions, appearance, required records and packing before shipment.
Special materials, finer geometry, heavier copper, unusual thicknesses and thermoelectric-separation structures require additional review before production.
These examples show common MCPCB constructions for different thermal, electrical and mechanical requirements. Final materials, dimensions, tolerances and inspection requirements are confirmed from the project files.

A copper circuit and thermal dielectric are bonded to an aluminum base for broad-area heat spreading and a direct mounting surface.

Selected two-layer constructions add routing density while retaining an aluminum thermal path and controlled electrical isolation.

Circuit features on both sides of the metal-core construction support denser electrical and assembly integration.

A multilayer circuit stack is integrated with a metal base when routing density and heat management must be solved in one construction.

Copper core construction supports higher heat and current demands when the added weight and cost are acceptable.

A raised copper feature shortens the heat path from a selected device pad while surrounding circuits retain electrical isolation.
Metal core PCBs are commonly used where heat dissipation, electrical isolation and mechanical mounting must be managed together.

High-bay, roadway and industrial lighting where LED junction heat, dielectric isolation and heat-sink contact drive the board construction.

Lighting, power conversion and control products requiring thermal cycling, traceability and controlled mechanical interfaces.

Inverters, charging equipment and power assemblies where heat spreading, current and enclosure contact must be coordinated.

Drives, power modules and control electronics designed for stable operation inside demanding equipment environments.
You can start with partial files. A complete data package helps us confirm the construction, price and lead time faster.
Send the project files, thermal targets and mechanical interface requirements. EBest PCBA will review the MCPCB construction and identify any open questions before preparing the quote.